- Control panels designed for two or more aspiration units are fitted with an electronic device to
start/stop one or more motors automatically according to aspiration need. - The connecting device for the electronic circuit of all electronic control panels (i.e. all control
panels marked by a fi nal E, like C 75/1E, C75/E etc.) must be completed with a peripheral P.B. unit
to be placed next to the tip support. - Two-fan aspiration units warm up proportionally to operating head value. If operating head gets
above 1500 mm H2O, the room must be adequately ventilated or conditioned; the installation of a
thermal compensating valve (supplied separately) is always recommended. - Each suction machine can service a variable number of dental units depending on different
parameters: diameter and length of the piping, number of bends, brand of the dental unit
(requirements concerning aspiration can vary), therefore the number of dental units we suggest
should not be considered as binding.
- Sound pressure level tested according to ISO regulation 3746 -1979 (E).
Parameters: r =1.5 – background noise < 51 dB (A) – Instrument: Brüel & Kjær type 2232.
The motor is protected by a thermal
device. Single-phase output power 0.4
kW – 3.1 A, maximum flow 1250 l/min,
maximum operating head for continuous
service 1300 mm H2O. Single-surgery
use. Sound pressure level with canalized
air 62 dB (A).
W= 231.5 mm D= 246 mm H= 251 mm
Net Weight= 10 kg (Gross Weight= 12 kg)
With control panel.
Sound pressure level with canalized air 58 dB (A).
W= 315 mm D= 280 mm H= 330 mm
Net Weight= 17 kg (Gross Weight= 20 kg)
Without control panel. Sound pressure
level with canalized air 58 dB (A).
W= 315 mm D= 280 mm H= 330 mm
Net Weight= 17 kg (Gross Weight= 20 kg)
Single-phase output power 0.75 kW – 5.5
A, maximum flow 2000 l/min,
maximum operating head for continuous
service 1400 mm H2O.
Suggested for 3 dental units working at
the same time.
Sound pressure level with canalized air
68 dB (A)
W= 302.5 mm D= 302 mm H= 319 mm
Net Weight= 18 kg (Gross Weight= 21 kg)
Three-phase output power 0.75 kW –
3.4/1.95 A, maximum flow 2000 l/min,
maximum operating head for continuous
service 1400 mm H2O.
Suggested for 3 dental units working at
the same time.
Sound pressure level with canalized air
68 dB (A)
W= 302.5 mm D= 302 mm H= 319 mm
Net Weight= 18 kg (Gross Weight= 21 kg)
Single-phase output power 0.75 kW – 5.5
A, maximum flow 2000 l/min,
maximum operating head for continuous
service 1400 mm H2O.
Suggested for 3 dental units working at
the same time.
Sound pressure level with canalized air
60 dB (A).
W= 390 mm D= 345 mm H= 410 mm.
Three-phase output power 0.75 kW –
3.4/1.95 A, maximum flow 2000 l/min,
maximum operating head for continuous
service 1400 mm H2O.
Suggested for 3 dental units working at
the same time.
Sound pressure level with canalized air
60 dB (A).
W= 390 mm D= 345 mm H= 410 mm.
Single-phase output power 0.75 kW – 5.5
A, maximum flow 2000 l/min,
maximum operating head for continuous
service 1400 mm H2O.
Suggested for 3 dental units working at
the same time.
Sound pressure level with canalized air
60 dB (A).
W= 390 mm D= 345 mm H= 410 mm.
For 2 Tecno-Jet units three-phase.
W= 400 mm D=220 mm H= 580 mm.
For 2 Tecno-Jet units single-phase.
W= 400 mm D=220 mm H= 580 mm.
Output power single-phase 1.1 kW –
7.6 A, maximum flow 3300 l/min, maximum
operating head for continuous service
1500 mm H2O.
Suggested for 4 surgeries working at the
same time.
Sound pressure level with canalized air
68.5 dB (A).
W= 334 mm D= 405 mm H= 341 mm
Net Weight= 22 kg (Gross Weight= 27 kg)
Output power three-phase 1.5 kW – 6.4/3.7A,
maximum flow 3300 l/min, maximum
operating head for continuous service
1500 mm H2O.
Suggested for 4 surgeries working at the
same time.
Sound pressure level with canalized air
68.5 dB (A).
W= 334 mm D= 405 mm H= 341 mm
Net Weight= 22 kg (Gross Weight= 27 kg)
Output power three-phase 1.5 kW – 6.4/3.7A,
maximum flow 3300 l/min, maximum
operating head for continuous service
1500 mm H2O.
Suggested for 4 surgeries working at the
same time.
Sound pressure level with canalized air
63 dB (A).
W= 520 mm D= 430 mm H= 510 mm.
Output power single-phase 1.1 kW –
7.6 A, maximum flow 3300 l/min, maximum
operating head for continuous service
1500 mm H2O.
Suggested for 4 surgeries working at the
same time.
Sound pressure level with canalized air
63 dB (A).
W= 520 mm D= 430 mm H= 510 mm.
Output power single-phase 1.1 kW –
7.6 A, maximum flow 3300 l/min, maximum
operating head for continuous service
1500 mm H2O.
Suggested for 4 surgeries working at the
same time.
Sound pressure level with canalized air
63 dB (A).
W= 520 mm D= 430 mm H= 510 mm.
For one Flux-Jet unit three-phase.
For one Flux-Jet unit single-phase.
For 2 Flux-Jet units single-phase.
W= 400 mm D= 220 mm H= 580 mm.
For 2 Flux-Jet units three-phase.
W= 400 mm D= 220 mm H= 580 mm.
For 3 Flux-Jet units three-phase.
W= 550 mm D= 250 mm H= 700 mm.
For 3 Flux-Jet units single-phase.
W= 550 mm D= 250 mm H= 700 mm.
Output power three-phase 2.2 kW – 9/5.2
A, maximum flow 5000 l/min, maximum
operating head for continuous service
1750 mm H2O.
Suggested for 7 surgeries working at the
same time. Sound pressure level with
canalized air 76 dB (A).
W= 395 mm D= 332 mm H= 415 mm
Net Weight= 30 kg (Gross Weight= 35 kg)
For 2 three-phase Medio-Jet units.
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 4 kW –
16.7/9.7 A, maximum flow 8333 l/min,
maximum operating head for continuous
service 1500 mm/H2O. Suggested for 12
surgeries working at the same time.
Sound pressure level with canalized air
76.5 dB (A).
W= 566 mm D= 422 mm H= 443 mm
Net Weight= 54 kg (Gross Weight= 60 kg)
For 2 three-phase Maxi-Jet 2S units.
W= 400 mm D= 220 mm H= 580 mm.
For 4 three-phase Maxi-Jet 2S units.
W= 550 mm D= 250 mm H= 700 mm.
For 3 three-phase Maxi-Jet 2S units
W= 550 mm D= 250 mm H= 700 mm.
The peripheral P.B. unit is required only
with electronic control panels (those
marked by a final E, like C75/1E, C75/E
etc.).
Each tip support has to be fitted with
one peripheral P.B. unit which must be
placed next to it.
W= 70 mm D= 70 mm H= 22 mm
Output power single-phase 0.70 kW –
5.2 A. Maximum flow 1330 l/min. Maximum
operating head for continuous service
2690 mm H2O.
Suggested for single-surgery use.
Sound pressure level with canalized air
64 dB (A).
W= 246 mm D= 491 mm H= 251 mm
Net Weight= 13 kg (Gross Weight= 15 kg)
Output power three-phase 0.75 kW – 3.4/1.95
A. Maximum flow 1330 l/min. Maximum
operating head for continuous service
2690 mm H2O.
Suggested for single-surgery use.
Sound pressure level with canalized air
64 dB (A).
W= 246 mm D= 491 mm H= 251 mm
Net Weight= 13 kg (Gross Weight= 15 kg)
Without control panel. Output power
threephase 0.75 kW – 3.4/1.95 A. Maximum
flow 1330 l/min.
Maximum operating head for continuous
service 2000 mm H2O. Suggested for
single-surgery use.
Without control panel.Sound pressure
level with canalized air 61.3 dB (A).
W= 520 mm D= 350 mm H= 320 mm
Net Weight= 25 kg (Gross Weight= 33 kg)
Without control panel. Output power
single-phase 0.70 kW – 5.2 A. Maximum
flow 1330 l/min.
Maximum operating head for continuous
service 2000 mm H2O. Suggested for
single-surgery use.
Without control panel.Sound pressure
level with canalized air 61.3 dB (A).
W= 520 mm D= 350 mm H= 320 mm
Net Weight= 25 kg (Gross Weight= 33 kg)
Output power single-phase 1.1 kW – 7.5
A. Maximum flow 2170 l/min.
Maximum operating head for continuous
service single-phase 2000 mm H2O,
three-phase 2350 mm H2O.
Suggested for 2 surgeries working at the
same time.
Sound pressure level with canalized air
65 dB (A).
W= 303 mm D= 543 mm H= 319 mm
Net Weight= 22 kg (Gross Weight= 27 kg)
Output power three-phase 1.5 kW – 6/3.5 A.
Maximum flow 2170 l/min.
Maximum operating head for continuous
service single-phase 2000 mm H2O,
three-phase 2350 mm H2O.
Suggested for 2 surgeries working at the
same time.
Sound pressure level with canalized air
65 dB (A).
W= 303 mm D= 543 mm H= 319 mm
Net Weight= 22 kg (Gross Weight= 27 kg)
For two Tecno-Jet 2V three-phase.
W= 400 mm D= 220 mm H= 580 mm.
For two Tecno-Jet 2V single-phase.
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 2.2 kW – 9/5.2
A. Maximum flow 3330 l/min. Maximum
operating head for continuous service
2350 mm H2O. Suggested for 4 surgeries
working at the same time. Sound
pressure level with canalized air 72 dB
(A). W= 334 mm D= 575 mm H= 341 mm
Net Weight= 30 kg (Gross Weight= 37 kg)
For 3 Flux-Jet 2V three-phase.
W= 550 mm D= 250 mm H= 700 mm.
For 2 Flux-Jet 2V three-phase.
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 4 kW –
16.7/9.7 A. Maximum flow 4830 l/min.
Maximum operating head for continuous
service 2450 mm H2O. Suggested for 7
surgeries working at the same time.
Sound pressure level with canalized air
72 dB (A).
W= 395 mm D= 705 mm H= 415 mm
Net Weight= 57 kg (Gross Weight= 66 kg)
For 2 Medio-Jet 2V three-phase.
W= 400 mm D= 220 mm H= 580 mm.
The end-of-line valve sets into operation
to boost the air inlet and to empty
any siphon hindering the regular and
constant suction.